Maintenance
Check the excavator's rotational speed and set the idle stop method
- 01 -
How can I check the rotational speed on the display screen
When the excavator experiences a stuck vehicle phenomenon, you can check whether the rotational speed has dropped, how many revolutions it has dropped, and whether the working condition is normal.
The method to check the rotational speed is as follows
Press and hold the buzzer switch, and at the same time turn the key switch to ON to enter the service diagnosis.
2. While holding down the buzzer, press the selection switch (the first button in the second row) three times, select Adjustment Mode 1 downward, and press the selection switch to confirm.
3. Use the wiper button and the water sprayer button to select the adjustment items up and down. When switching to "Display Speed", press the selection switch to confirm entering this option. Select ON and press the selection switch again to confirm.
4. When you need to check the rotational speed, press the display switch to switch to the rotational speed display page.
- 02 -
Automatic idle stop
The functions are as follows
No.1 Save fuel;
After the No.2 engine automatically shuts off, the exhaust emissions are zero, which is beneficial to environmental protection.
No.3: Extend engine life. When the engine is idling, the fuel cannot be completely burned, which is prone to cause carbon deposits in the engine. Carbon deposits in the engine will burn oil, increase energy consumption, and reduce the engine's power output.
The method for setting the automatic idle stop is as follows
Press and hold the buzzer switch, and at the same time turn the key switch to ON to enter the service diagnosis.
2. While holding down the buzzer, press the selection switch (the first button in the second row) three times, select Adjustment Mode 1 downward, and press the selection switch to confirm.
3. Use the wiper button to select the adjustment items. When switching to automatic stop, press the selection on/off key to confirm.
4. Use the wipers and water sprayer. Select the automatic idle stop time by pressing the up and down selection keys. Press the selection on/off key to confirm. It can be adjusted between 60 and 600. If set to 999, the idle stop will be lifted.
Related articles
- These 15 precautions for operating bulldozers should be well understood!
- The more skills you have, the better! Two maintenance methods for road rollers
- The excavator won't start. How can I solve this problem?
- Do a good job of checking the motor grader before starting it every day, and the boss's salary incre
- Is there crawling in the hydraulic system? Noise? "Technical sharing to solve your worries!&quo
- Guide you step by step to understand the commissioning procedure of a concrete mixing plant!To ensur
- Allison has launched the eGen PowerTM fully integrated zero-emission electric drive axle for medium
- Nord has launched the brand-new MAXXDRIVE®XT industrial gearbox - a powerful transmission device sui
- Even people in Shaanxi Province praise, "The Guangkang engine is so beautiful!"
- The Allison FuelSense® 2.0 transmission saves 12% of fuel for the Marseille - Provence metropolis