Farming
Inspection and maintenance of the electrical control system of the straw feed baling machine
Sensor
1. Maintenance cycle
Check every working day.
2. Inspection and judgment
Check if the sensor is loose and whether the distance between the magnet and the sensor is reasonable (the standard distance for Hall sensors is 5mm-10mm; the standard distance between inductive sensors and the travel rod of the push cylinder is 1mm-1.5mm)
3. Maintenance and care
Adjust the nut with a wrench and observe that the sensor indicator light is on.
Wiring harnesses and connectors
1. Maintenance cycle
Check every working day.
2. Inspection and judgment
Check if the joints are loose and if the power connection is overheating. (Including: main control wiring harness, automatic winding wiring harness, display terminal and power connection wiring)
3. Maintenance and care
If the plug-in parts of the connector are loose or fallen off, they need to be re-plugged or replaced. If the power connector gets hot due to poor contact, the contact surface should be properly treated and tightened. If the wiring harness is damaged, the damaged area should be wrapped with insulating tape for waterproof and dustproof treatment
Related articles
- Reasons for and solutions to the non-rotation fault of the excavator
- What are the requirements for the inspection and repair of the half-shaft sleeve?
- How to repair the wheels and tires of a forklift?
- Performance Characteristics and Usage Advantages of the Manure Scraper Machine
- Selection and Maintenance of the New Fruit Picker
- Use and Maintenance of Magnetic Drive Pumps
- When the battery of the agricultural protection drone bulges, the handling method is as follows.
- A Brief Discussion on the Maintenance of Pipe Chain Conveyors
- Hester: A reliable material handling solution for food and beverage industries
- The 2022 Linde "Material Handling World" exhibition came to a successful conclusion in Man